Orifice Plate Compact Flange
Single Pressure Tapping Series for Insertion between Compact FlangesMEF/5

The orifice plates compact flange are used as primary elements in flow measurement according to the differential pressure principle. The tapping arrangement is corner tapping.
Design and calculation standards :
- ISO 5167-2 2003, ASME MFC-3M, NORSOK L-005, Shell Flow Meter Engineering Handbook
- Sizes : DN 50 - 600, 2" - 24"
- β (d/D) : 0,1 < β < 0,75
- Pressure rating : 300 - 2500 lbs
- Orifice plate : Integrated with holder
- Plate thickness : 3 – 6 mm
- Vent or drain hole : On request
- Material : AISI 316, 22 Cr Duplex, 25 Cr Duplex, 6Mo, other materials on request.
- Mounting style : Between flanges with IX grooves according to NORSOK L-005
- Orifice plate : Square edge concentric, square edge eccentric, conical, 1/4 circle, segment.
- The plate is bevelled on the down stream side except for 1/4 circle orifice plate.
- Pressure taps : Threaded: 1⁄2" NPT int. (standard) or 1⁄2" BSP. Flanged: 1⁄2" and 3⁄4", 300, 600, 1500 and 2500 lbs IX or RTJ.
- Tap location : At least 15° apart, depending on size and pressure rating.
- Marking : The orifice plate is marked with "+" and "-" and flow direction.
- Handle : With name plate in AISI 316 with the following inscription :TAG no., serial no., pressure rating, inner pipe diameter, bore, material.

Technical Data
- Accuracy : +/- 0,5 % for β < 0,6 and equal to β for β values above 0,6
- Pressure loss : Depending on β, for β equal to 0,6 : ca. 60 % of the differential pressure measured
- Limits for Reynolds No : Re(D) > 5000 for 0,1< β < 0,56 and Re(D) > 16000 x β 2 for β > 0,56 according to ISO 5167-2 2003 2000 < Re < 108 according to ASME MFC-3M
Dimensions
| Size | Pressure rating lbs | |||||
|---|---|---|---|---|---|---|
| 300 | 600 | 900 | 1500 | 2500 | ||
| 2” | Width (w) | 40 | 40 | 40 | 40 | 40 |
| OD | Ø132 | Ø136 | Ø136 | Ø136 | Ø147 | |
| 3” | Width (w) | 40 | 40 | 40 | 40 | 40 |
| OD | Ø161 | Ø161 | Ø161 | Ø180 | Ø209 | |
| 4” | Width (w) | 40 | 40 | 40 | 40 | 40 |
| OD | Ø186 | Ø203 | Ø203 | Ø224 | Ø248 | |
| 6” | Width (w) | 50 | 50 | 50 | 50 | 50 |
| OD | Ø240 | Ø258 | Ø263 | Ø307 | Ø322 | |
| 8” | Width (w) | 50 | 50 | 50 | 50 | 50 |
| OD | Ø306 | Ø312 | Ø330 | Ø365 | Ø408 | |
| 10” | Width (w) | 50 | 50 | 50 | 50 | 50 |
| OD | Ø361 | Ø382 | Ø397 | Ø453 | Ø485 | |
| 12” | Width (w) | 60 | 60 | 60 | 60 | 60 |
| OD | Ø415 | Ø450 | Ø462 | Ø508 | Ø564 | |
| 14” | Width (w) | 60 | 60 | 60 | 60 | 60 |
| OD | Ø450 | Ø482 | Ø497 | Ø558 | Ø618 | |
| 16” | Width (w) | 60 | 60 | 60 | 60 | 60 |
| OD | Ø519 | Ø547 | Ø567 | Ø626 | Ø718 | |
| 18” | Width (w) | 70 | 70 | 70 | 70 | 70 |
| OD | Ø567 | Ø614 | Ø633 | Ø704 | Ø780 | |
| 20” | Width (w) | 70 | 70 | 70 | 70 | 70 |
| OD | Ø631 | Ø664 | Ø700 | Ø778 | Ø849 | |
| 24” | Width (w) | 70 | 70 | 70 | 70 | 70 |
| OD | Ø750 | Ø785 | Ø830 | Ø933 | Ø1039 |
Works with:-
Differential pressure transmitters:-IDP10; IDP15; IDP25; IDP31; IDP50
And all our Absolute Pressure and Gauge Pressure transmitters, Temperature sensors and mass flow computers.
MultiVariable Transmitters :- IMV25, IMV30
Download Datasheet Orifice Plate Flowmeter with Single Pressure Tappings for insertion between Compact Flanges
Download Manual (Not Available)
If you require further information on this product or would like a quotation, please contact dp-flow on:
email: sales@dp-flow.co.uk
sales +44(0)1608 544222
Supplied by DP-Flow